Description
Location
Event
Select the position for the bottom edge
of the box mask on the selected key
for the selected ME.
Switcher
>
Keyer
>
Box
Mask Param
Mask (Box) —
Bottom Edge
Position
Mask (Box)
— Bottom Edge
Position
1.
Click the
ME
button for the ME
that you want to perform the
event on.
2.
Click the
Keyer
button for the
key you want to perform the
event on.
3.
Click the
Parameter
button and
select
Bottom Edge
.
4.
Click the
Change Type
button
and select whether you want to
set (
Absolute
) or reset (
Reset
)
the parameter. Some selections
will not be available when you
reset the parameter.
5.
Enter a new position in the
Value (%)
field.
Select the position for the left edge of
the box mask on the selected key for
the selected ME.
Switcher
>
Keyer
>
Box
Mask Param
Mask (Box) — Left
Edge Position
1.
Click the
ME
button for the ME
that you want to perform the
event on.
2.
Click the
Keyer
button for the
key you want to perform the
event on.
3.
Click the
Parameter
button and
select
Left Edge
.
4.
Click the
Change Type
button
and select whether you want to
set (
Absolute
) or reset (
Reset
)
the parameter. Some selections
will not be available when you
reset the parameter.
5.
Enter a new position in the
Value (%)
field.
Select the position for the right edge
of the box mask on the selected key
for the selected ME.
Switcher
>
Keyer
>
Box
Mask Param
Mask (Box) —
Right Edge
Position
1.
Click the
ME
button for the ME
that you want to perform the
event on.
2.
Click the
Keyer
button for the
key you want to perform the
event on.
3.
Click the
Parameter
button and
select
Right Edge
.
4.
Click the
Change Type
button
and select whether you want to
set (
Absolute
) or reset (
Reset
)
the parameter. Some selections
will not be available when you
reset the parameter.
5.
Enter a new position in the
Value (%)
field.
Select the size of the box mask on the
selected key for the selected ME.
Switcher
>
Keyer
>
Box
Mask Param
Mask (Box) — Size
1.
Click the
ME
button for the ME
that you want to perform the
event on.
2.
Click the
Keyer
button for the
key you want to perform the
event on.
Description
Location
Event
3.
Click the
Parameter
button and
select
Size
.
4.
Click the
Change Type
button
and select whether you want to
set (
Absolute
) or reset (
Reset
)
the parameter. Some selections
will not be available when you
reset the parameter.
5.
Enter a new size in the
Value
(%)
field.
Select the position for the top edge of
the box mask on the selected key for
the selected ME.
Switcher
>
Keyer
>
Box
Mask Param
Mask (Box) — Top
Edge Position
1.
Click the
ME
button for the ME
that you want to perform the
event on.
2.
Click the
Keyer
button for the
key you want to perform the
event on.
3.
Click the
Parameter
button and
select
Top Edge
.
4.
Click the
Change Type
button
and select whether you want to
set (
Absolute
) or reset (
Reset
)
the parameter. Some selections
will not be available when you
reset the parameter.
5.
Enter a new position in the
Value (%)
field.
Select the x-axis position of the box
mask on the selected key for the
selected ME.
Switcher
>
Keyer
>
Box
Mask Param
Mask (Box) —
X-Position
1.
Click the
ME
button for the ME
that you want to perform the
event on.
2.
Click the
Keyer
button for the
key you want to perform the
event on.
3.
Click the
Parameter
button and
select
X-Pos
.
4.
Click the
Change Type
button
and select whether you want to
set (
Absolute
) or reset (
Reset
)
the parameter. Some selections
will not be available when you
reset the parameter.
5.
Enter a new position in the
Value (%)
field.
Select the y-axis position for the box
mask on the selected key for the
selected ME.
Switcher
>
Keyer
>
Box
Mask Param
Mask (Box) —
Y-Position
1.
Click the
ME
button for the ME
that you want to perform the
event on.
2.
Click the
Keyer
button for the
key you want to perform the
event on.
3.
Click the
Parameter
button and
select
Y-Pos
.
4.
Click the
Change Type
button
and select whether you want to
set (
Absolute
) or reset (
Reset
)
the parameter. Some selections
will not be available when you
reset the parameter.
5.
Enter a new position in the
Value (%)
field.
Carbonite Operation Manual (v13.0) — Custom Controls •