1.5.3.4 Frequency Error Measurement
Total frequency error of a burst
Syntax:
Execute new
measurement and signal
result
Read result only
READ[:SCALar]:BURSt:FREQuency:ERRor?
FETCh[:SCALar]:BURSt:FREQuency:ERRor?
Return:
<value>
(current, unit: Hz)
<value> (average,
unit:
Hz)
<value>
(maximum, unit: Hz)
State:
MCE, RFG,
BAN
Option:
none Query only
Note:
No default values, (N5), (N7)
1.5.4
Timing Measurement
Syntax:
Execute new
measurement and signal
result
Read result only
READ[:SCALar]:BURSt:TIMing:ERRor?
FETCh[:SCALar]:BURSt:TIMing:ERRor?
Return:
<value> (unit:
Bit)
State:
MCE
Option:
none Query only
Note:
No default values, (N5), (N7)