CTS55
List of Commands/Annex C
1094.0006.55 C.33
E-8
1.6
Miscellaneous
1.6.1
Internal Instrument State
Current instrument state
Syntax:
STATus:DEVice?
Return:
IDLE
|
Idle (initial state)
MIDL
|
MS test: Idle
MSYN
|
MS test: Synched
MCE
|
MS test: Call established
MOD
|
Module test Idle
IQSP
|
IQ-spectrum
BAN
|
Burst Analysis
RFG RF
generator
Default:
IDLE
State:
ALL
Option:
none Query only
1.6.2
Mobile Station Details
Query for Mobile Stations Extended GSM capabilities
Syntax:
CALCulate:MOBILE:EGSM:STATus?
Return:
NSUP
Not
Supported
SUPP
Supported
State:
MSYN or
MCE
Option:
none Query only
Default:
NSUP
Query for Mobile Stations Dual Band capabilities
Syntax:
CALCulate:MOBILE:DBHO:STATus?
Return:
NSUP
Not
Supported
SUPP
Supported
State:
MSYN or
MCE
Option:
none Query only
Note:
Capability for 900 / 1800MHz only.
Default:
NSUP
Содержание 1094.0006.50
Страница 4: ......
Страница 12: ......
Страница 22: ......
Страница 24: ......
Страница 26: ......
Страница 28: ......
Страница 30: ......
Страница 41: ...CTS55 Getting Started With Autotest 1094 0006 55 3 3 E 7...
Страница 66: ......
Страница 81: ...CTS55 Getting Started With Manual Test 1094 0006 55 6 7 E 6...
Страница 83: ...CTS55 Getting Started With Manual Test 1094 0006 55 6 9 E 6...
Страница 106: ......
Страница 108: ......
Страница 196: ......
Страница 246: ......
Страница 250: ......
Страница 253: ...CTS55 Index 1094 0006 55 I 3 E 8 V Viewing angle 2 3 Voltage selector 2 3 Voltage selector switch 2 2...
Страница 254: ......
Страница 256: ......
Страница 343: ...CTS K6 Windows Application CTSgo 1079 2001 01 87 E 3 Fig CTSgo help window...