RX610 Group
23. A/D Converter
R01UH0032EJ0120 Rev.1.20
Page 797 of 1006
Feb 20, 2013
23.3.6
Activation by the Compare-Match/Input-Capture A Signals from TPU0 to TPU5
The compare-match/input-capture A signals from TPU0 to TPU5 are capable of starting A/D conversion by units 0 to 3.
The compare-match/input-capture A signals from TPU6 to TPU11 are also capable of starting A/D conversion by units 0
to 3.
The connections between the units of the converter and the compare-match/input-capture A signals are shown in figure
23.11.
The compare-match/input-capture A signals from TPU0 to TPU5 are capable of simultaneously starting A/D conversion
by a maximum of all four converter units. Setting the ADn.ADCR.TRGS[2:0] bits (n = 0 to 3) to 001b (specifying the
compare-match/input-capture A signals from TPU0 to TPU5) and setting the TTGE bits in the TIERs of TPU0 and TPU2
to 1 set up the compare-match/input-capture A signals from TPU0 and TPU2 as the triggers that start simultaneous
conversion by units 0 to 3.
AD0.ADCR.TRGS[2:0]
A/D conversion start trigger
A/D converter unit 0
TPU unit 0
Compare-match/input-
capture A signal
TPU0
TPU0.TIER.TTGE
Compare-match/input-
capture A signal
TPU5
TPU5.TIER.TTGE
TPU unit 1
TPU6
TPU11
Compare-match/input-
capture A signal
Compare-match/input-
capture A signal
TPU6.TIER.TTGE
TPU11.TIER.TTGE
AD1.ADCR.TRGS[2:0]
A/D conversion start trigger
A/D converter unit 1
AD2.ADCR.TRGS[2:0]
A/D conversion start trigger
A/D converter unit 2
AD3.ADCR.TRGS[2:0]
A/D conversion start trigger
A/D converter unit 3
Figure 23.11 Connections between Compare-Match/Input-Capture A Signals
and the Respective Converter Units