RX610 Group
16. Programmable Pulse Generator (PPG)
R01UH0032EJ0120 Rev.1.20
Page 545 of 1006
Feb 20, 2013
•
PPG1.PMR
Bit
Symbol
Bit Name
Description
R/W
b0
G0NOV
Group 4 Non-Overlap
0: Normal operation
(Output values updated on compare match A in the
selected TPUm)
1: Non-overlapping operation
(Output values updated on compare match A or B in the
selected TPUm)
(m = 0 to 3, 6 to 9)
R/W
b1
G1NOV
Group 5 Non-Overlap
0: Normal operation
(Output values updated on compare match A in the
selected TPUm)
1: Non-overlapping operation
(Output values updated on compare match A or B in the
selected TPUm)
(m = 0 to 3, 6 to 9)
R/W
b2
G2NOV
Group 6 Non-Overlap
0: Normal operation
(Output values updated on compare match A in the
selected TPUm)
1: Non-overlapping operation
(Output values updated on compare match A or B in the
selected TPUm)
(m = 0 to 3, 6 to 9)
R/W
b3
G3NOV
Group 7 Non-Overlap
0: Normal operation
(Output values updated on compare match A in the
selected TPUm)
1: Non-overlapping operation
(Output values updated on compare match A or B in the
selected TPUm)
(m = 0 to 3, 6 to 9)
R/W
b4
G0INV
Group 4 Output Polarity Invert 0: Inverted output
1: Direct output
R/W
b5
G1INV
Group 5 Output Polarity Invert 0: Inverted output
1: Direct output
R/W
b6
G2INV
Group 6 Output Polarity Invert 0: Inverted output
1: Direct output
R/W
b7
G3INV
Group 7 Output Polarity Invert 0: Inverted output
1: Direct output
R/W
PPGm.PCR (m = 0, 1) selects the pulse output mode of the PPG on a group-by-group basis.
While inverted output is selected, a low-level pulse is output when the values in PPGm.PODRH and PPGm.PODRL are 1,
and a high-level pulse is output when the values in PPGm.PODRH and PPGm.PODRL are 0.
In addition, when non-overlapping operation is selected, the PPG updates its output values on compare match A or B in a
TPU channel that functions as an output trigger.
For details, see section 16.3.4, Non-Overlapping Pulse Output.