RX610 Group
16. Programmable Pulse Generator (PPG)
R01UH0032EJ0120 Rev.1.20
Page 530 of 1006
Feb 20, 2013
16.2.1
PPG Trigger Select Register (PTRSLR)
Address: 0008 81F0h
b7
b6
b5
b4
b3
b2
b1
b0
Value after reset:
0
0
0
0
0
0
0
1
—
—
—
—
—
—
—
PTRSL
•
PPG1.PTRSLR
Bit
Symbol
Bit Name
Description
R/W
b0
PTRSL
PPG Trigger Select
0: Selects the set of TPU0 toTPU3 as the trigger channels
for PPG1.
1: Selects the set of TPU6 to TPU9 as the trigger channels
for PPG1.
R/W
b7 to b1
Reserved
These bits are always read as 0. The write value should
always be 0.
R/W
PPG1.PTRSLR selects a set of trigger channels.
PTRSL Bit (PPG Trigger Select)
This bit selects either TPU0 to TPU3 or TPU6 to TPU9 as a set of trigger channels for PPG1.
When this bit is set to 0, TPU0 to TPU3 are selected as a set of trigger channels for PPG1.When it is set to 1, TPU6 to
TPU9 are selected as a set of trigger channels for PPG1.
PPG (unit 0) compare match input
PPG (unit 1) compare match input
PTRSLR.PTRSL
TPU
PPG
Compare match/input capture output in TPU0
Compare match/input capture output in TPU1
Compare match/input capture output in TPU2
Compare match/input capture output in TPU3
Compare match/input capture output in TPU6
Compare match/input capture output in TPU7
Compare match/input capture output in TPU8
Compare match/input capture output in TPU9
Figure 16.3 Block Diagram of PPG Trigger Selection