Remote Commands
R&S
®
FSW
1125
User Manual 1173.9411.02 ─ 43
Commands required to export traces (and other result data) are described in
ter 14.9.5, "Storing Measurement Results"
...............................................................................1125
...................................................................................1132
....................................................................................1139
..................................................................................... 1141
Formats for Returned Values: ASCII Format and Binary Format
Importing and Exporting Traces
.......................................................................... 1146
Programming Example: Configuring a Spectrogram
...........................................1148
14.8.2.1
Configuring Standard Traces
Useful commands for trace configuration described elsewhere
●
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y:SPACing
●
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]
Remote commands exclusive to trace configuration
DISPlay[:WINDow<n>]:TRACe<t>:MODE
.......................................................................1125
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE:HCONtinuous
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:PRESet
.......................................... 1127
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>[:STATe]
...........................................1127
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:SMOothing:APERture
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:SMOothing[:STATe]
..........................1128
...................................................................................... 1129
................................................................................. 1129
........................................................................................ 1129
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]
............................................................. 1130
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]:AUTO
................................................... 1131
DISPlay[:WINDow<n>]:TRACe<t>:MODE
<Mode>
This command selects the trace mode. If necessary, the selected trace is also activa-
ted.
In case of max hold, min hold or average trace mode, you can set the number of single
measurements with
. Note that synchronization to the end of
the measurement is possible only in single sweep mode.
Suffix:
<n>
.
Analyzing Measurements (Basics)