CALCulate<n>:LIMit<li>:ACPower:GAP<gap>:ACLR:RESult?
The command returns the ACLR power limit check results for the selected gap channel
in an MSR ACLR measurement.
To get a valid result, you have to perform a complete measurement with synchroniza-
tion to the end of the measurement before reading out the result. This is only possible
for single sweep mode.
See also
The results of the power limit checks are also indicated in the
STAT:QUES:ACPL
sta-
tus registry (see
"STATus:QUEStionable:ACPLimit Register"
Suffix:
<n>
.
1..n
<li>
1..n
irrelevant
<gap>
1 | 2
Gap (CACLR) channel number
Return values:
<LowerGap_AB>
<UpperGap_AB>
<LowerGap_BC>
<UpperGap_BC>
<LowerGap_CD>
<UpperGap_CD>
<LowerGap_DE>
<UpperGap_DE>
Example:
INIT:IMM;*WAI;
CALC:LIM:ACP:GAP2:ACLR:RES?
PASSED,PASSED
Usage:
Query only
CALCulate<n>:LIMit<li>:ACPower:GAP<gap>[:CACLr]:RESult?
The command returns the limit check results for the upper and lower gap (CACLR)
channels for the selected gap in an MSR ACLR measurement.
To get a valid result, you have to perform a complete measurement with synchroniza-
tion to the end of the measurement before reading out the result. This is only possible
for single sweep mode.
See also
The results of the power limit checks are also indicated in the
STAT:QUES:ACPL
sta-
tus registry (see
"STATus:QUEStionable:ACPLimit Register"