Remote Commands
R&S
®
FSW
980
User Manual 1173.9411.02 ─ 43
CALCulate<n>:MARKer<m>:FUNCtion:SUMMary:PPEak[:STATe]
<State>
This command turns the evaluation to determine the positive peak time domain power
on and off.
The R&S
FSW performs the measurement on the trace marker 1 is positioned on.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:SUMMary:RMS[:STATe]
<State>
This command turns the evaluation to determine the RMS time domain power on and
off.
The R&S
FSW performs the measurement on the trace marker 1 is positioned on.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:SUMMary:SDEViation[:STATe]
<State>
This command turns the evaluation to determine the standard deviation of the time
domain power on and off.
The R&S
FSW performs the measurement on the trace marker 1 is positioned on.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
14.5.10.2
Performing a Time Domain Power Measurement
The following commands are required to perform a Time Domain Power measurement:
Configuring and Performing Measurements
Содержание FSW Series
Страница 1: ...R S FSW Signal and Spectrum Analyzer User Manual User Manual Version 43 1173941102 2...
Страница 16: ...Contents R S FSW 16 User Manual 1173 9411 02 43...
Страница 1388: ...Maintenance R S FSW 1388 User Manual 1173 9411 02 43 c If necessary remove any excess moisture with a dry soft cloth Cleaning...