The required spacing can be determined according to the following formula:
Spacing = [CF of the gap channel] - [left sub block center] + ([RF bandwidth of left sub
block] /2)
Suffix:
<gap>
.
1 | 2
Gap channel number
Parameters:
<Spacing>
Default unit: HZ
Parameters for setting and query:
<SBGaps>
AB | BC | CD | DE | EF | FG | GH
Name of the gap, defined by the letters of the surrounding sub
blocks (e.g. "AB" for the gap between sub blocks A and B).
Example:
POW:ACH:SPAC:GAP:MAN:LOW AB, 5MHz
Example:
See
"Example: Configuring and Performing an Asymmetrical
Manual operation:
See
[SENSe:]POWer:ACHannel:SPACing:GAP<gap>:MANual:UPPer
<SBGaps>,
<Spacing>
[SENSe:]POWer:ACHannel:SPACing:GAP<gap>:MANual:UPPer?
<SBGaps>
This command defines the distance from the sub block to the specified upper gap
channel.
The required spacing can be determined according to the following formula:
Spacing = [right sub block CF] - [CF of gap channel] - ([RF
band-
width
of
right
sub
block]
/2)
Suffix:
<gap>
.
1 | 2
irrelevant
Parameters:
<Spacing>
Default unit: HZ
Parameters for setting and query:
<SBGaps>
AB | BC | CD | DE | EF | FG | GH
Name of the gap, defined by the letters of the surrounding sub
blocks (e.g. "AB" for the gap between sub blocks A and B).
Example:
POW:ACH:SPAC:GAP:MAN:UPP AB,5MHz
Example:
See
"Example: Configuring and Performing an Asymmetrical
Manual operation:
See
Configuring and Performing Measurements
Содержание FSW Series
Страница 1: ...R S FSW Signal and Spectrum Analyzer User Manual User Manual Version 43 1173941102 2...
Страница 16: ...Contents R S FSW 16 User Manual 1173 9411 02 43...
Страница 1388: ...Maintenance R S FSW 1388 User Manual 1173 9411 02 43 c If necessary remove any excess moisture with a dry soft cloth Cleaning...