A - 17
Appendices
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
A
-2 P
arameter Lis
t
A
Vibration Suppression Function Parameters
Pn
No.
Name
Setting
Description
Default
setting
Unit
Setting
range
Cycle the
power
supply
200
Adaptive Filter
Selection
Set the operation of the adaptive filter.
0
–
0 to 4
–
0
Disabled
1
One filter enabled. Frequency limit
applied when enabled.
2
Two filters enabled. Frequency limit
applied when enabled.
3
One filter always enabled.
4
Two filters enabled, one of which is
always enabled.
201
Notch 1
Frequency
Setting
Set the notch frequency of the first resonance
suppression notch filter.
5,000
Hz
50 to
5,000
–
202
Notch 1 Width
Setting
Set the notch width of the first resonance
suppression notch filter.
2
–
0 to 20
–
203
Notch 1 Depth
Setting
Set the notch depth of the first resonance
suppression notch filter.
0
–
0 to 99
–
204
Notch 2
Frequency
Setting
Set the notch frequency of the second
resonance suppression notch filter.
5,000
Hz
50 to
5,000
–
205
Notch 2 Width
Setting
Set the notch width of the second resonance
suppression notch filter.
2
–
0 to 20
–
206
Notch 2 Depth
Setting
Set the notch depth of the second resonance
suppression notch filter.
0
–
0 to 99
–
207
Notch 3
Frequency
Setting
Set the notch frequency of the third resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
5,000
Hz
50 to
5,000
–
208
Notch 3 Width
Setting
Set the notch width of the third resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
2
–
0 to 20
–
209
Notch 3 Depth
Setting
Set the notch depth of the third resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
0
–
0 to 99
–
210
Notch 4
Frequency
Setting
Set the notch frequency of the fourth resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
5,000
Hz
50 to
5,000
–
211
Notch 4 Width
Setting
Set the notch width of the fourth resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
2
–
0 to 20
–
212
Notch 4 Depth
Setting
Set the notch depth of the fourth resonance
suppression notch filter.
This parameter is automatically set when the
adaptive filter is enabled.
0
–
0 to 99
–
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......