7 - 57
7 Parameter Details
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
7-7 Speci
al P
arameter
s
7
• Set the time required for the Brake Interlock Output (BKIR: CN1 pin 10) to turn OFF after the
Operation Command (RUN: CN1 pin 29) is detected to be OFF, when servo OFF status is entered
while the Servomotor is operating.
When the Operation Command (RUN) turns OFF while the Servomotor is operating, the motor
decelerates to reduce rotation speed, and the Brake Interlock Output (BKIR) turns ON after the set
time elapsed.
“TB” in the above figure is the setting time in Brake Timing During Operation or the time until the
motor rotation speed falls to 30 r/min or lower, whichever is shorter.
• For details, refer to 6-6 Brake Interlock on page 6-18.
• Set the overspeed detection level in the event of an immediate stop alarm.
• The overspeed detection level is 1.2 times the maximum rotation speed of the Servomotor if this
parameter is set to 0.
• This parameter should normally be set to 0. The setting should be changed only when it is necessary
to lower the overspeed detection level.
• The set value of this parameter is limited to 1.2 times the maximum rotation speed of the Servomotor.
• Do not set.
Pn614
Alarm Detection Allowable Time Setting
Setting
range
0 to 1,000
Unit
ms
Default
setting
200
Cycle the
power supply
–
Pn615
Overspeed Detection Level Setting at Immediate Stop
Setting
range
0 to 20,000
Unit
r/min
Default
setting
0
Cycle the
power supply
–
Pn616
Reserved
Setting
range
1
Unit
–
Default
setting
1
Cycle the
power supply
–
All
T
B
Operation Command (RUN)
Brake Interlock Output (BKIR)
Motor speed
Motor power is supplied
30 r/min
Released
Held
No power
supply
Power supply
All
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......