5 Basic Control Mode
5 - 10
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
With a step speed command, the speed command can be changed based on the setting to reduce the
shock caused by change in acceleration.
Soft Start Acceleration Time (Pn312) and Soft Start Deceleration Time
(Pn313)
For a step speed command input, set the time until the command speed reaches 1
,000
r/min in Soft
Start Acceleration Time (Pn312). Similarly, set the time until the command speed slows from 1,000
r/min down to 0 r/min in Soft Start Deceleration Time (Pn313).
Soft Start Acceleration Time [ms] = Vc/1,000 x Pn312 x 1 ms
Soft Start Deceleration Time [ms] = Vc/1,000 x Pn313 x 1 ms
Speed Command Acceleration/Deceleration Setting Function
(Pn312, Pn313, Pn314)
Parameter
No.
Name
Description
Setting
range
Unit
Pn312
Soft Start Acceleration
Time
Set the acceleration time for the
speed command input.
0 to 10,000
ms/
(1,000 r/min)
Pn313
Soft Start Deceleration
Time
Set the deceleration time for the
speed command input.
0 to 10,000
ms/
(1,000 r/min)
Pn314
S-curve Acceleration/
Deceleration Time Setting
Set the first internal speed.
0 to 1,000
ms
1,000 r/min
Pn312 × 1 ms
Pn313 × 1 ms
Step speed command input
Speed command after
acceleration or
deceleration process
Speed [r/min]
Time t
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......