A - 27
Appendices
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
A
-2 P
arameter Lis
t
A
Pn
No.
Name
Setting
Description
Default
setting
Unit
Setting
range
Cycle the
power
supply
517
Error Counter
Reset
Condition
Selection
Set the condition for clearing the Error Counter
Reset Input signal.
3
–
0 to 4
–
0
Disabled
1
Clear the error counter with the level.
(Shorted for 500 µs or longer)
2
Clear the error counter with the level.
(Shorted for 1 ms or longer)
3
Clear the error counter with the edge.
(Change from open to shorted for
100 µs or longer)
4
Clear the error counter with the edge.
(Change from open to shorted 1 ms
or longer)
518
Command
Pulse
Prohibition
Input Setting
Set whether to enable or disable the command
pulse prohibition input signal (INH).
1
–
0 to 1
–
0
Enabled
1
Disabled
519
Command
Pulse
Prohibition
Input Read
Setting
Select the signal read cycle for the Command
Pulse Prohibition Input.
0
–
0 to 4
Required
0
0.166 ms
1
0.333 ms
2
1 ms
3
1.666 ms
4
0.166 ms
520
Position Setting
Unit Selection
Select the setting unit of Position Completion
Range 1/2 and Error Counter Overflow Level.
0
–
0 to 1
Required
0
Command unit
1
Encoder unit
521
Torque Limit
Selection
Select the forward or reverse torque limit
selection method.
1
–
0 to 6
–
0
Reserved (Do not set.)
1
Limit in both forward and reverse
directions set in Pn013
2
Forward: Set in Pn013, Reverse: Set
in Pn522
3
When TL-SEL input is open: Set in
Pn013
When TL-SEL input is shorted: Set in
Pn522
4
Reserved (Do not set.)
5
Reserved (Do not set.)
6
When TL-SEL input is open: Limit in
forward direction set in Pn013, limit in
reverse direction set in Pn522
When TL-SEL input is shorted: Limit
in forward direction set in Pn525, limit
in reverse direction set in Pn526
522
No. 2 Torque
Limit
Set the second output torque limit of the
Servomotor.
500
%
0 to
500
–
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......