10 - 9
10 Troubleshooting and Maintenance
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
10-3 A
larm Li
st
10
*1
“Immediate stop” means alarms which cause an immediate stop when Stop Selection for Alarm Detection
(Pn510) is set to 4 to 7. For details, refer to Stop Selection for Alarm Detection on page 7-46.
87
0
Emergency Stop Input
Error
An emergency stop input signal (STOP)
was input.
–
√
–
95
0-4
Motor Non-conformity
The combination of the Servomotor and
Servo Drive is not appropriate.
The encoder was not connected when the
power supply was turned ON.
–
–
–
Other
numbers
Other errors
The control circuit malfunctioned due to
excess noise or some other problem.
√
–
–
Alarm No.
Error detection function
Description and error cause
Attribute
Main
Sub
History
Can be
cleared
Immediate
stop
*1
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......