6 - 31
6 Applied Functions
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
6-8 T
o
rq
ue L
imit
6
6-8-1 Outline o
f the Fun
c
tion
6-8
Torque Limit
• The torque limit function limits the output torque of the Servomotor.
• This function is used in the following conditions.
• When push-motion operation, such as pressing, is performed.
• When the torque at startup and during deceleration should be suppressed to protect mechanical
systems, etc.
• Various torque limit options can be set in Torque Limit Selection (Pn521).
• When torque feed-forward is selected, the torque limit function is enabled only during speed control
when the set value is 1 to 3.
6-8-1
Outline of the Function
Parameter
No.
Name
Description
Reference
Pn521
Torque Limit Selection
Select the torque limit based on the various
parameters and input signals.
Pn013
No. 1 Torque Limit
Set the first motor output torque limit value.
Pn522
No. 2 Torque Limit
Set the second motor output torque limit value.
Pn523
Torque Limit Switching Setting 1 Set the rate of change (fluctuation) when switching
from No. 1 Torque Limit to No. 2 Torque Limit.
Pn524
Torque Limit Switching Setting 2 Set the rate of change (fluctuation) when switching
from No. 2 Torque Limit to No. 1 Torque Limit.
Pn525
Forward External Torque Limit
Set the forward torque limit based on a network signal.
Pn526
Reverse External Torque Limit
Set the reverse torque limit based on a network signal.
Torque Limit in Position/Speed Control
Pn521 set value
Description
0
Reserved (Do not set.)
1
Limit in both forward and reverse directions: Set in Pn013
2
Forward: Set in Pn013
Reverse: Set in Pn522
3
Switching the limit value by the torque limit switching (TLSEL)
When TLSEL is OFF
Limit in both forward and reverse directions: Set in Pn013
When TLSEL is ON
Limit in both forward and reverse directions: Set in Pn522
4
Reserved (Do not set.)
5
Reserved (Do not set.)
6
Switching the limit value by the torque limit switching (TLSEL)
When TLSEL is OFF
Forward: Set in Pn013
Reverse: Set in Pn522
When TLSEL is ON
Forward: Set in Pn525
Reverse: Set in Pn526
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......