6 - 33
6 Applied Functions
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
6-9 Seq
u
en
ce I/O Signa
ls
6
6-9-1 Outline o
f the Fun
c
tion
6-9
Sequence I/O Signals
• You can set sequences in various operating conditions.
• For the connection of I/O signals and processing of external signals, refer to 3-1-4 Control I/O
Connector Specifications (CN1) on page 3-9.
You can allocate any functions to the input pins of the control I/O connector (CN1). In addition, you can
change the logic. However, some signals have limitations in the allocation. Refer to Input Signal
Allocation Method on page 6-34 for details.
If you replace a G-series Servo Drive, use the G5-series Servo Drive with the default settings.
The allocations of the default input signals are as follows. Refer to Input Signal Allocation Method on
page 6-34 when you change the allocation to use.
NO and NC in the Logic column above refer to the following states.
NO:
Disabled (OFF) when signal input is open with COM-
Enabled (ON) when signal input is shorted with COM-
NC:
Disabled (OFF) when signal input is shorted with COM-
Enabled (ON) when signal input is open with COM-
6-9-1
Outline of the Function
6-9-2
Input Signals
Default Input Signal Settings
Parameter
Input
signal
Default setting
Default setting state
Position control
Speed control
Signal
logic
Signal
logic
Pn400
SI1
00828282 hex (8553090)
NOT
NC
NOT
NC
Pn401
SI2
00818181 hex (8487297)
POT
NC
POT
NC
Pn402
SI3
0091910A hex (9539850)
DFSEL1
NO
VZERO
NC
Pn403
SI4
00060606 hex (394758)
GSEL
NO
GSEL
NO
Pn404
SI5
0000100C hex (4108)
GESEL1
NO
VSEL3
NO
Pn405
SI6
00030303 hex (1979379)
RUN
NO
RUN
NO
Pn406
SI7
00000f07 hex (3847)
ECRST
NO
VSEL2
NO
Pn407
SI8
00040404 hex (263172)
RESET
NO
RESET
NO
Pn408
SI9
00050505 hex (328965)
TVSEL
NO
TVSEL
NO
Pn409
SI10
00000E88 hex (3720)
IPG
NC
VSEL1
NO
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......