Appendices
A - 24
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
Expansion Setting Parameters
Pn
No.
Name
Setting
Description
Default
setting
Unit
Setting
range
Cycle the
power
supply
500
Electronic Gear
Ratio
Numerator 2
Set the electronic gear ratio.
If Pn500, Pn501, or Pn502 = 0, the encoder
resolution is set in the numerator.
0
–
0 to 2
30
–
501
Electronic Gear
Ratio
Numerator 3
0
–
0 to 2
30
–
502
Electronic Gear
Ratio
Numerator 4
0
–
0 to 2
30
–
503
Encoder
Dividing
Denominator
Set the denominator if the number of pulses per
motor rotation is not an integer in pulse
regeneration.
0
–
0 to
262,144
Required
504
Drive
Prohibition
Input Selection
Set the operation to be performed upon forward/
reverse drive prohibition input.
1
–
0 to 2
Required
0
Forward or reverse drive prohibition
input enabled
1
Forward or reverse drive prohibition
input disabled
2
Forward or reverse drive prohibition
input enabled
505
Stop Selection
for Drive
Prohibition
Input
Make the setting upon drive prohibition input.
0
–
0 to 2
Required
0
The torque in the drive prohibit
direction is disabled, and the
dynamic brake is activated.
1
The torque in the drive prohibit
direction is disabled, and free-run
deceleration is performed.
2
The torque in the drive prohibit
direction is disabled, and an
immediate stop is performed.
Electronic Gear Ratio Denominator (Pn010)
Electronic Gear Ratio Numerator 2 (Pn500)
or
Electronic Gear Ratio Numerator 3 (Pn501)
or
Electronic Gear Ratio Numerator 4 (Pn502)
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......