7 - 19
7 Parameter Details
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
7-2 Gain
P
arameter
s
7
• Set the hysteresis width above and below the judgment level set in Gain Switching Level in Speed
Control (Pn122). The unit depends on the setting of Switching Mode in Speed Control (Pn120).
The definitions of Gain Switching Delay Time in Speed Control (Pn121), Gain Switching Level in
Speed Control (Pn122), and Gain Switching Hysteresis in Speed Control (Pn123) are shown in the
drawing below.
• The settings for Gain Switching Level in Speed Control (Pn122) and Gain Switching Hysteresis in
Speed Control (Pn123) are enabled as absolute values (forward/reverse).
• Do not set.
• Do not set.
• Do not set.
• Do not set.
Pn123
Gain Switching Hysteresis in Speed Control
Setting
range
0 to 20,000
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn124
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn125
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn126
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
Pn127
Reserved
Setting
range
0
Unit
–
Default
setting
0
Cycle the
power supply
–
Speed
Pn122
0
Pn123
Pn121
Gain 1
Gain 2
Gain 1
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......