Appendices
A - 18
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
213
Damping Filter
Selection
Set the switching method for damping filters.
0
–
0 to 3
–
0
Enabled
1
When DF-SEL1 input is open:
Damping filters 1 and 3 enabled
When DF-SEL1 input is shorted:
Damping filters 2 and 4 enabled
2
When both DF-SEL1 and DF-SEL2
are open:
Damping filter 1 enabled
When DF-SEL1 is shorted and DF-
SEL2 is open:
Damping filter 2 enabled
When DF-SEL1 is open and DF-
SEL2 is shorted:
Damping filter 3 enabled
When both DF-SEL1 and DF-SEL2
are shorted:
Damping filter 4 enabled
3
Forward direction:
Damping filters 1 and 3 enabled
Reverse direction:
Damping filters 2 and 4 enabled
214
Damping
Frequency 1
Set the first damping frequency. The minimum
allowable setting is 10 (= 1 Hz).
0
0.1 Hz
0 to
2,000
–
215
Damping Filter
1 Setting
Make fine adjustment to the first damping
control function. Set a smaller value if torque
saturation occurs or a larger value to increase
the responsiveness.
0
0.1 Hz
0 to
1,000
–
216
Damping
Frequency 2
Set the second damping frequency. The
minimum allowable setting is 10 (= 1 Hz).
0
0.1 Hz
0 to
2,000
–
217
Damping Filter
2 Setting
Make fine adjustment to the second damping
control function. Set a smaller value if torque
saturation occurs or a larger value to increase
the responsiveness.
0
0.1 Hz
0 to
1,000
–
218
Damping
Frequency 3
Set the third damping frequency. The minimum
allowable setting is 10 (= 1 Hz).
0
0.1 Hz
0 to
2,000
–
219
Damping Filter
3 Setting
Make fine adjustment to the third damping
control function. Set a smaller value if torque
saturation occurs or a larger value to increase
the responsiveness.
0
0.1 Hz
0 to
1,000
–
220
Damping
Frequency 4
Set the fourth damping frequency. The minimum
allowable setting is 10 (= 1 Hz).
0
0.1 Hz
0 to
2,000
–
221
Damping Filter
4 Setting
Make fine adjustment to the fourth damping
control function. Set a smaller value if torque
saturation occurs or a larger value to increase
the responsiveness.
0
0.1 Hz
0 to
1,000
–
222
Position
Command
Filter Time
Constant
Set the first-order lag filter time constant for the
position command.
0
0.1
ms
0 to
10,000
–
223
Smoothing
Filter Time
Constant
Set the FIR filter time constant for the position
command.
0
0.1
ms
0 to
10,000
–
Pn
No.
Name
Setting
Description
Default
setting
Unit
Setting
range
Cycle the
power
supply
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......