A - 19
Appendices
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
A
-2 P
arameter Lis
t
A
Speed Control Parameters
Pn
No.
Name
Setting
Description
Default
setting
Unit
Setting
range
Cycle the
power
supply
300
Command
Speed
Selection
Select the speed command in the speed control
mode.
1
–
1 to 3
–
0
Disabled
1
No. 1 Internally Set Speed to No. 4
Internally Set Speed (Pn304 to
Pn307)
2
Reserved
(Do not set.)
3
No. 1 Internally Set Speed to No. 8
Internally Set Speed (Pn304 to
Pn311)
301
Speed
Command
Direction
Selection
Select the method to specify the speed
command direction.
0
–
0 to 1
–
0
By a sign
1
By VSIGN
302
Reserved
Do not set.
500
–
500
–
303
Reserved
Do not set.
1
–
1
–
304
No. 1 Internally
Set Speed
Set the first internal speed command value.
0
r/min
–20,000
to
20,000
–
305
No. 2 Internally
Set Speed
Set the second internal speed command value.
0
r/min
–
306
No. 3 Internally
Set Speed
Set the third internal speed command value.
0
r/min
–
307
No. 4 Internally
Set Speed
Set the fourth internal speed command value.
0
r/min
–
308
No. 5 Internally
Set Speed
Set the fifth internal speed command value.
0
r/min
–
309
No. 6 Internally
Set Speed
Set the sixth internal speed command value.
0
r/min
–
310
No. 7 Internally
Set Speed
Set the seventh internal speed command value.
0
r/min
–
311
No. 8 Internally
Set Speed
Set the eighth internal speed command value.
0
r/min
–
312
Soft Start
Acceleration
Time
Set the acceleration time relative to the speed
command.
0
ms/
(1,000
r/min)
0 to
10,000
–
313
Soft Start
Deceleration
Time
Set the deceleration time relative to the speed
command.
0
ms/
(1,000
r/min)
0 to
10,000
–
314
S-curve
Acceleration/
Deceleration
Time Setting
Set the acceleration or deceleration S-curve
time for the speed command.
0
ms
0 to
1,000
–
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......