6 - 5
6 Applied Functions
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
6-1 D
a
mp
ing
Con
tr
o
l
6
6-1-2 P
ar
ameters R
equir
ing
Settings
3
Make the damping filter settings.
Make damping filter settings (1: Pn215, 2: Pn217, 3: Pn219, 4: Pn221).
First, set to 0.
The stabilization time can be reduced by setting a large value; however, torque ripple will
increase at the command change point as shown in the following figure. Set a range that will not
cause torque saturation under actual operation conditions. The effects of vibration suppression
will be lost if torque saturation occurs.
When Damping Frequency 1 (Pn214) is set, reduce this setting if torque saturation occurs or
increase this setting to improve the operation speed. Normally 0 is set.
When Damping Filter 1 is enabled, the setting range is as follows:
Setting range: 100
≤
Pn214 + Pn215
≤
Pn214 x 2 or 2,000
Note When Damping Filter 1 is disabled in Damping Filter Selection (Pn213), this parameter is also
disabled.
4
Set the Damping Filter Selection (Pn213).
Damping Filter 1 to 4 can be switched according to the conditions of the machine vibration.
Set value
Switching mode
0
Damping Filter 1 and 2 enabled
1
Switching via external input (DFSEL1)
When DFSEL1 is open: Damping Filter 1 and 3 enabled
When DFSEL1 is shorted: Damping Filter 2 and 4 enabled
2
Switching via external input (DFSEL1, DFSEL2)
When DFSEL1 and DFSEL2 are open: Damping Filter 1 enabled
When DFSEL1 is shorted and DFSEL2 is open: Damping Filter 2 enabled
When DFSEL1 is open and DFSEL2 is shorted: Damping Filter 3 enabled
When DFSEL1 and DFSEL2 are shorted: Damping Filter 4 enabled
3
Switching based on the command direction
During forward rotation: Damping Filter 1 and 3 enabled
During reverse rotation: Damping Filter 2 and 4 enabled
Torque
command
Torque saturation
Damping filter setting is
too large.
Damping filter setting
is appropriate.
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......