10 Troubleshooting and Maintenance
10 - 4
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
Use the following procedure to replace the Servomotor or Servo Drive.
1
Replace the motor.
2
Perform origin adjustment (for position control).
• When the motor is replaced, the motor’s origin position (phase Z) may deviate, so origin
adjustment must be performed.
• Refer to the position controller’s manual for details on performing origin adjustment.
1
Take a record of all parameter settings.
Use the operation keys on the Servo Drive to write down all the contents of parameter settings.
2
Replace the Servo Drive.
3
Set the parameters.
Use the operation keys on the Servo Drive to set all of the parameters.
10-1-3 Replacing the Servomotor or Servo Drive
Replacing the Servomotor
Replacing the Servo Drive
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......