5 - 7
5 Basic Control Mode
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
5-2 Inter
n
all
y
Set Speed
Con
tr
o
l
5
5-2-1 Outline
of the Fu
nction
5-2
Internally Set Speed Control
• The Internally Set Speed Control function controls the speed of the Servomotor based on the speeds
set in the No. 1 to 8 Internally Speed Settings.
• Select the internally set speed using Internally Set Speed Selection 1 to 3 of the control input terminals
(VSEL1: CN1 pin 33, VSEL2: CN1 pin 30, VSEL3: CN1 pin 28).
5-2-1
Outline of the Function
5-2-2
Parameters Requiring Settings
Parameter
No.
Name
Description
Reference
Pn001
Control Mode Selection
Select the control mode in which the Internally Set Speed
Control function can be used. (Set value: 1, 3)
Pn300
Command speed Selection
Select the speed command input method.
Pn304
No. 1 Internally Set Speed
Set the internally set speeds [r/min].
The valid setting range is from -20,000 to 20,000 r/min. Be
sure to set the speeds within the allowable range of rotation
speed of the motor.
Pn305
No. 2 Internally Set Speed
Pn306
No. 3 Internally Set Speed
Pn307
No. 4 Internally Set Speed
Pn308
No. 5 Internally Set Speed
Pn309
No. 6 Internally Set Speed
Pn310
No. 7 Internally Set Speed
Pn311
No. 8 Internally Set Speed
Pn312
Soft Start Acceleration Time
Set the acceleration time for Internally Set Speed Control.
Set the time until the Servomotor reaches 1,000 r/min.
Pn313
Soft Start Deceleration Time
Set the deceleration time for Internally Set Speed Control.
Set the time until the Servomotor reaches 1,000 r/min.
Pn314
S-curve Acceleration/
Deceleration Time Setting
Set the S-curve time in the time width centered on the inflection
points for acceleration and deceleration.
AC Servo Drive
OMNUC G5-series
(Pulse-train Input Type)
AC Servomotor
OMNUC G5-series
(Pulse-train Input Type)
Contorller
VSEL3
VSEL2
VSEL1
Internally Set
Speed 1 to 8
(Pn304 to 311)
Internally Set Speed Control
Speed Selection
Command
* Internally set
speed control can
be performed
with digital I/O
signals only.
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......