3 Specifications
3 - 20
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
When to Input a Command Pulse (Line Receiver Input)
Command pulse mode
Detailed timing
Feed Pulse/Direction Signal
Maximum input frequency
Line driver:
4 Mpps
Reverse Pulse/Forward Pulse
Maximum input frequency
Line driver:
4 Mpps
90° Phase Difference Signal
Maximum input frequency
Line driver:
4 Mpps
t1
t1
t2
t2
t2
t1
t1
T
τ
t 1 ≤ 20 ns
t 2 > 500 ns
τ ≥ 250 ns
T ≥ 500 ns
(τ/T) x 100 ≤ 50 (%)
Direction
signal
Feed pulse
Forward rotation command
Reverse rotation command
t 1 ≤ 20 ns
t 2 > 500 ns
τ ≥ 250 ns
T ≥ 500 ns
(τ/T) x 100 ≤ 50 (%)
T
τ
t2
t1
t1
Reverse pulse
Forward pulse
Forward rotation command
Reverse rotation command
t1 ≤ 20 ns
τ ≥ 4.0 µs
T ≥ 8.0 µs
(τ/T) x 100 ≤ 50 (%)
t1
t1
T
τ
Phase-A pulse
Phase-B pulse
Forward rotation command
Reverse rotation command
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......