7 - 25
7 Parameter Details
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
7-3 Vibration Su
pp
re
ssion
P
arameter
s
7
• Set the time constant for the FIR filter applied to the command pulses. (FIR: Finite Impulse
Response)
• Setting a larger value improves the smoothness of the command pulse input.
Pn223
Smoothing Filter Time Constant
Setting
range
0 to 10,000
Unit
0.1 ms
Default
setting
0
Cycle the
power supply
–
Position
Input position
command
Position command after
FIR filter processing
t
f
t
f
t
f
= (Pn223 × 0.1 ms)