6 Applied Functions
6 - 36
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
• The functions that are used by more than one control mode (such as Operation Command and
Alarm Reset Input) must be allocated to the same pin with the same logic. If they are not set
correctly, Interface Input Duplicate Allocation Error 1 (Alarm No. 33.0) or Interface Input
Duplicate Allocation Error 2 (Alarm No. 33.1) will occur.
• The Operation Command (RUN) must be allocated. Servo cannot be turned ON if it is not
allocated.
You can allocate any functions to the output pins of the control I/O connector (CN1).
If you replace a G-series Servo Drive, use the G5-series Servo Drive with the default settings.
The allocations of the default output signals are as follows. Refer to Output Signal Allocation Method on
page 6-37 when you change the allocation to use.
*1
Alarm output signal allocation cannot be changed.
Use the following parameters when changing the output signal allocations.
For the setting method, refer to Output Signal Allocation Method on page 6-37.
6-9-3
Output Signals
Default Output Signal Settings
Parameter
Output signal
Default setting
Default setting state
Position control
Speed control
Signal
Signal
Pn410
SO1
00030303 hex (197379)
BKIR
BKIR
Pn411
SO2
00020202 hex (131586)
READY
READY
Pn412
SO3
*1
ALM
ALM
Pn413
SO4
00050504 hex (328964)
INP
TGON
Parameters That can be Allocated
Parameter
No.
Name
Description
Reference
Pn410
Output Signal
Selection 1
Set the SO1 output function allocation. This
parameter must be set in hexadecimal notation. For
the setting method, refer to the Function Number
Table of output signals.
Pn411
Output Signal
Selection 2
Set the SO2 output function allocation.
Pn412
Output Signal
Selection 3
Set the SO3 output function allocation. This
parameter is fixed to the alarm output signal.
Pn413
Output Signal
Selection 4
Set the SO4 output function allocation.
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......