A - 13
Appendices
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
A
-2 P
arameter Lis
t
A
*1
The default setting is 11 for a Servo Drive with 200 V and 1 kW or more.
*2
The default setting is 0 for a Servo Drive with 200 V and 750 W or more.
016
Regeneration
Resistor
Selection
Select the Regeneration Resistor to be used.
3
*2
–
0 to 3
Required
0
Uses the Built-in Resistor.
The Regeneration Overload
Protection (Alarm No.18) is enabled
according to the Built-in Resistor
(with approx. 1% duty).
1
Uses the External Resistor.
The regeneration processing circuit
operates and Regeneration Overload
Protection (Alarm No.18) is enabled
when the operating rate of the
Regeneration Resistor is over 10%.
2
Uses the External Resistor.
Regeneration Overload Protection
(Alarm No.18) is disabled.
3
No Regeneration Resistors.
All regenerative energy is processed
by the built-in capacitor.
017
External
Regeneration
Resistor
Setting
Select the load ratio calculation type for the
External Regeneration Resistor.
0
–
0
Required
0
Regeneration load ratio is 100%
when the operating rate of the
External Regeneration Resistor is
10%.
1
Reserved
2
Reserved
3
Reserved
4
Reserved
Pn
No.
Name
Setting
Description
Default
setting
Unit
Setting
range
Cycle the
power
supply
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......