10 Troubleshooting and Maintenance
10 - 8
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
29
0
Error Counter Overflow
Error counter value based on the encoder
pulse reference exceeded 2
29
(536,870,912).
√
√
–
33
0
Interface Input Duplicate
Allocation Error 1
A duplicate setting for the interface input
signals was detected.
√
–
–
1
Interface Input Duplicate
Allocation Error 2
√
–
–
2
Interface Input Function
Number Error 1
An undefined number was detected in the
interface input signal allocations.
√
–
-–
3
Interface Input Function
Number Error 2
√
–
–
4
Interface Output Function
Number Error 1
An undefined number was detected in the
interface output signal allocations.
√
–
–
5
Interface Output Function
Number Error 2
√
–
–
6
Counter Reset
Allocation Error
The counter reset function was allocated to
something other than input signal SI7.
√
–
–
7
Command Pulse
Prohibition Input
Allocation Error
The command pulse prohibition input
function was allocated to something other
than input signal SI10.
√
–
–
34
0
Overrun Limit Error
The motor exceeded the allowable
operating range set in the Overrun Limit
Setting (Pn514) with respect to the position
command input.
√
√
–
36
0-2
Parameter Error
Data in the Parameter Save area was
corrupted when the power supply was
turned ON and data was read from the
EEPROM.
–
–
–
37
0-2
Parameter destruction
The checksum for the data read from the
EEPROM when the power supply was
turned ON does not match.
–
–
–
38
0
Drive Prohibition Input
Error
The forward drive prohibition and reverse
drive prohibition inputs are both turned
OFF.
–
√
–
43
0
Encoder Initialization Error An encoder initialization error was
detected.
√
–
–
44
0
Encoder 1-rotation
Counter Error
A 1-turn counter error was detected.
√
–
–
45
0
Multi-rotation Counter
Error
A multi-rotation counter error or phase-AB
signal error was detected.
√
–
–
48
0
Encoder Phase-Z Error
A serial incremental encoder phase Z
pulse irregularity was detected.
√
–
–
49
0
Encoder CS Signal Error
A logic error was detected in the CS signal
for serial incremental encoder.
√
–
–
55
0
Phase-A Connection Error
An error was detected in the external
encoder phase A connection.
√
–
–
1
Phase-B Connection Error
An error was detected in the external
encoder phase B connection.
√
–
–
2
Phase-Z Connection Error
An error was detected in the external
encoder phase Z connection.
√
–
–
Alarm No.
Error detection function
Description and error cause
Attribute
Main
Sub
History
Can be
cleared
Immediate
stop
*1
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......