3 Specifications
3 - 48
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
Brake Specifications
*1
These are the values when the Servomotor is combined with a Servo Drive at normal temperature (20°C, 65%). The
momentary maximum torque indicates the standard value.
*2
Applicable load inertia
• The operable load inertia ratio (load inertia/rotor inertia) depends on the mechanical configuration and its rigidity. For a
machine with high rigidity, operation is possible even with high load inertia. Select an appropriate motor and confirm
that operation is possible.
• The dynamic brake is rated for short-term operation. Use it only for emergency stopping. Configure the system to stop
for at least three minutes after the dynamic brake operates. Otherwise, the dynamic brake circuits may fail or the
dynamic brake resistor may burn.
*3
The allowable radial and thrust loads are the values determined for a limit of 20,000 hours at normal operating
temperatures.
The allowable radial loads are applied as shown in the following diagram.
*4
This is a non-excitation brake. (It is released when excitation voltage is applied.)
*5
The operation time is the value (reference value) measured with a surge suppressor (CR50500 by Okaya Electric
Industries Co., Ltd.).
*6
Direct current switching with a varistor (TNR9G820K by Nippon Chemi-Con Corporation).
*7
Direct current switching with a varistor (Z15D151 by Ishizuka Electronics Co.).
Model (R88M-)
200 VAC
Item
Unit
KE3K020H
KE4K020H
KE5K020H
Brake inertia
kg·m
2
1.35 x 10
-4
4.7 x 10
-4
4.7 x 10
-4
Excitation voltage
*4
V
24 VDC±10%
Power consumption (at 20°C)
W
22
31
31
Current consumption (at 20°C)
A
0.90±10%
1.3±10%
1.3±10%
Static friction torque
N·m
16.2 min.
24.5 min.
24.5 min.
Attraction time
*5
ms
110 max.
80 max.
80 max.
Release time
*5
ms
50 max.
*6
25 max.
*7
25 max.
*7
Backlash
±1°
Allowable work per braking
J
1,470
1,372
1,372
Allowable total work
J
2.2 x 10
6
20.9 x 10
6
2.9 x 10
6
Allowable angular acceleration
rad/s
2
10,000
Brake life
–
10 million times min.
Rating
–
Continuous
Insulation class
–
Class F
Radial load
Thrust load
Shaft center (T/2)
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......