*1
The value is regarded as 115% if set to 115 or higher.
510
Stop Selection
for Alarm
Detection
Set the operation sequence in case of an alarm.
0
–
0 to 7
–
0
During deceleration: Dynamic brake
After stopping: Dynamic brake
1
During deceleration: Free-run
After stopping: Dynamic brake
2
During deceleration: Dynamic brake
After stopping: Servo-free
3
During deceleration: Free-run
After stopping: Servo-free
4
During deceleration by immediate
stop alarm: Immediate stop
During deceleration: Dynamic brake
After stopping: Dynamic brake
5
During deceleration by immediate
stop alarm: Immediate stop
During deceleration: Free-run
After stopping: Dynamic brake
6
During deceleration by immediate
stop alarm: Immediate stop
During deceleration: Dynamic brake
After stopping: Servo-free
7
During deceleration by immediate
stop alarm: Immediate stop
During deceleration: Free-run
After stopping: Servo-free
511
Immediate Stop
Torque
Set the torque limit for immediate stop.
0
%
0 to
500
–
512
Overload
Detection Level
Setting
Set the overload detection level.
0
%
0 to
500
*1
–
513
Overspeed
Detection Level
Setting
Set the overspeed error detection level.
0
r/min
0 to
20,000
–
514
Overrun Limit
Setting
Set the amount of Servomotor overrun for the
position command.
10
0.1
rotation
0 to
1,000
–
515
Control Input
Signal Read
Setting
Select the signal read cycle for the interface
from the following four levels.
0
–
0 to 3
Required
0
0.166 ms
1
0.333 ms
2
1 ms
3
1.666 ms
516
Alarm Reset
Condition
Setting
Set the alarm clear input detection method.
0
–
0 to 1
Required
0
120 ms
1
Follow the setting of Control Input
Signal Read Setting (Pn515).
Pn
No.
Name
Setting
Description
Default
setting
Unit
Setting
range
Cycle the
power
supply
Содержание G5 R88D-KE Series
Страница 3: ...2 Page 2 53 For 1 000 r min Servomotors 900 W to 3 kW Current Contents Corrected Contents...
Страница 22: ...Manual Structure 18 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 334: ...6 Applied Functions 6 52 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 396: ...7 Parameter Details 7 62 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 426: ...8 Operation 8 30 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 498: ...Appendices A 32 OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual...
Страница 499: ...Index 1 I OMNUC G5 series Pulse train Input Type AC Servomotors and Servo Drives User s Manual Index...
Страница 504: ......
Страница 505: ......