Appendices
A-6
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
n+8
n+18
15 to 00
*_P1_TransErrSta
*_P2_TransErrSta
Transmission Error Status
15
*_P1_TransErr
*_P2_TransErr
Transmission error
14
*_P1_TfsErr
*_P2_TfsErr
Tfs (Send Finished Monitoring Time)
Exceeded
13
*_P1_TfrErr
*_P2_TfrErr
Tfr (Receive Finished Monitoring
Time) Exceeded
12
*_P1_TrErr
*_P2_TrErr
Tr (Receive Wait Monitoring Time)
Exceeded
11 to 08
Bit 11 to 08 of
*_P1_TransErrSta
Bit 11 to 08 of
*_P2_TransErrSta
Retry Count
07
*_P1_FCSErr
*_P2_FCSErr
FCS Check Error
06
*_P1_CmdErr
*_P2_CmdErr
Command Error
05
*_P1_TimeoutErr
*_P2_TimeoutErr
Timeout Error
04
*_P1_OverRunErr
*_P2_OverRunErr
Overrun Error
03
*_P1_FramingErr
*_P2_FramingErr
Framing Error
02
*_P1_ParityErr
*_P2_ParityErr
Parity Error
01, 00
---
---
Reserved
CJ-series I/O memory Address
NJ-series device variable for CJ-series Unit
Word No.
Bit No.
Variable name
Meaning
Port 1
Port 2
Port 1
Port 2
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...