R-73
A Standard System Protocol
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
R-4 V50
0
/V
520 Bar
Code Reader
Pr
otoc
o
l
Re
f
R
-4-3
Protocol
Configur
ation
This sequence sets preset data.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Preset Data Set (V500) (Sequence No. 357 (Hex 0165))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
18N+2 (N is number of presets 1 to 5)
+1 Number
of
presets
(1 digit BCD)
1 to 5
+2
Preset data No.
(1 digit BCD)
1 to 5
+3
Data length
(2 digits BCD)
01 to 32
+4 to +19 Preset data (ASCII)
Combination of the following ASCII characters and up to 32
characters maximum:
30 ('0') to 39 ('9')
41 ('A') to 5A ('Z'), 3F ('?')
The area that is not used is undefined
+20 to
+91
Store repeatedly the contents of words with o2 to +19
the same number of times as the number of presets (N)
First word of
(Undefined)
Number of data
+0
+1
+2
+3
+4
+5
+18
+19
+(18N+2)
+(18N+3)
+(18N+4)
+(18N+5)
+(18N+18)
+(18N+19)
Number of send data words
send data
Preset data
(Undefined)
Number of presets
Preset data
(Undefined)
Preset data No.
(Undefined)
Preset data No.
Preset data
Preset data
Preset data
(Undefined)
Number of data
Preset data
Preset data
Preset data
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...