A Standard System Protocol
R-124
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Operand and Send/Receive Data Word Settings of PMCR(260)
Setting Example
When send data is THIS IS SAMPLE.
A maximum of 200 bytes (including the CR) can be received. When the received data is RETURN
OK, the content stored in the receive words is as follows:
Additional Information
An error will occur if the reception data is not received within 90 seconds after the data is sent.
Shifting to the escape mode can be made using sequence No. 554. No setting is necessary for this
sequence.
Additional Information
The character string to shift the online mode to the escape mode (i.e., the escape code) is '+' for
modem settings.
The hang up command (to disconnect the line) can be executed using sequence No. 555. No setting is
necessary for this sequence.
OPR 2
#0229
OPR 3
First address C1 of the words where send data is set
OPR 4
First address C2 of the words where receive data is stored
• Send Data Words
C1+0
Number of words from address set for operand 2 to end of data
4 digits Hex
C1+1
Number of bytes of send data
4 digits Hex
C1+2
:
C1+n
Send data (dialling operation)
(Fill data to left for odd numbers of bytes)
ASCII
• Receive Data Storage Words
C2+0
Number of bytes of receive data
4 digits Hex
C2+1
:
C2+n
Receive data (dialling operation)
(Fill data to left for odd numbers of bytes)
ASCII
Escape (Sequence No. 554 (Hex 022A))
Hang Up (Sequence No. 555 (Hex 022B))
Character string length of send data sent to modem (bytes)
Code length of PMCR(260) when it is used (words)
000E
0009
5448
T H
4953
I S
2049
I
5320
S
5341
S A
4D50
M P
4C45
L E
Length of received character string (words)
0006
5245
R E
5455
T U
524E
R N
204F
O
4B00
K
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...