This sequence writes the word data starting from the specified word + 7 in the CS/CJ-series CPU Unit
to the number of device points starting from the specified device address for the specified device type
(except T, C) in the Mitsubishi Computer Link Module with the specified station number (and the PLC
number that follows).
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260)
Device Memory Fill as Word Data (All Device Types Except T/C)
(Sequence No. 812 (Hex 032C)) (Command Code: QW)
Offset
Contents (data format)
Data
+0
Number of send data words (4 digits hex)
0008 to 00FA hex (8 to 250 decimal)
+1
Station No.
(2 digits hex)
PLC No.
(2 digits hex)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
+2
(Undefined) Device
type
(2 digits hex)
Set the device type (1 character) in ASCII.
+3
Device No. (6 digits hex)
Set the first write address of the write data.
+4
(Undefined)
+5
(Undefined) Device
points
(2 digits hex)
Set the device points to write.
+6
Number of send data bytes (4 digits hex)
Specify the number of text data bytes for the com-
munications line (i.e., twice the number of text
bytes in S+7 onwards)
+7
on
Write data (4 digits hex)
Set the write data.
Offset
Contents (data format)
Data
+0
Number of receive data words
0002 hex or 0003 hex (2 or 3 decimal)
+1
Station No.
(2 digits hex)
PLC No.
(2 digits hex)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
+2
Error code
(2 digits hex)
(Undefined)
Stores the error code converted to hexadecimal.
No error code is stored for normal completion.
+0
+1
+5
+2
+3
+4
+6
+7
on
Number of send data words
PLC No.
Station No.
Number of send data bytes
Device type
(Undefined)
Device No.
Write data
First word of
send data
(Undefined)
(Undefined)
Device points
Receive data
storage words
Number of receive data words
+0
+1
PLC No.
+2
Station No.
Error code
(Undefined)
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...