A Standard System Protocol
R-82
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
The hexadecimal equivalents of sequences numbers are given in parentheses.
*1
Normal responses will be returned for these sequences for 5000-series and 6000-series Laser Micrometers,
but no processing will be performed.
*2
This sequence will be processed the same as sequence No. 425 AVG move (H) times set for 5000-series
Laser Micrometers.
*3
Memory switch settings will be ignored for these sequences for 5000-series and 6000-series Laser Microme-
ters.
*4
This sequence will be processed the same as sequence No. 411 Zero run measurement start for 5000-series
Laser Micrometers.
416 (01A0)
Statistic processing execution (3000-series)
Yes
Yes
417 (01A1)
Statistic processing non-execution (3000-series)
Yes
Yes
418 (01A2)
All statistic memory clear (3000-series)
Yes
Yes
419 (01A3)
Statistic memory clear (3000-series)
Yes
Yes
420 (01A4)
Statistic result request (3000-series)
No
No
421 (01A5)
Memory switch set 1 (3000-series)
No
*1
No
*1
422 (01A6)
Memory switch set 2 (3000-series)
No
*1
No
*1
423 (01A7)
Simple AVG times set (3000-series)
Yes
Yes
424 (01A8)
AVG move interval set (3000-series)
Yes
Yes
425 (01A9)
AVG move (H) times set (3000-series)
Yes
Yes
426 (01AA)
AVG move (L) times set (3000-series)
Yes*
2
No
427 (01AB)
Automatic detection set (3000-series)
No
No
428 (01AC)
Automatic detection release (3000-series)
Yes
Yes
429 (01AD)
Automatic detection list request (3000-series)
Yes
Yes
430 (01AE)
3Z4L initialize (3000-series)
Yes
*3
Yes
*3
431 (01AF)
Measurement condition set (4000-series)
No
No
432 (01B0)
Measurement condition release (4000-series)
No
No
433 (01B1)
Measurement condition list request (4000-series)
No
No
434 (01B2)
Single run measurement start (4000-series)
Yes
No
435 (01B3)
Deflection measurement start (4000-series)
Yes
*4
No
436 (01B4)
Continuous measurement start (scan) (4000-series)
Yes
No
437 (01B5)
Continuous measurement start (interrupt) (4000-series)
Yes
No
438 (01B6)
Measurement termination (4000-series)
Yes
No
439 (01B7)
Data request (4000-series)
Yes
No
440 (01B8)
Forced positive zero (4000-series)
Yes
Yes
441 (01B9)
Forced negative zero (4000-series)
Yes
Yes
442 (01BA)
Forced zero release (4000-series)
Yes
Yes
443 (01BB)
3Z4L initialize (4000-series)
Yes
*3
Yes
*3
444 (01BC)
General-purpose command 1
Yes
Yes
445 (01BD)
General-purpose command 2
Yes
Yes
446 (01BE)
High calibration set
No
No
447 (01BF)
Low calibration set
No
No
Sequence
No.
Communications sequence name
Operation
5000 Series
6000 Series
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...