A Standard System Protocol
R-84
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
422 (01A6)
Memory switch set 2
(3000-series)
Sets memory switches.
Yes
No
423 (01A7)
Simple AVG times set
(3000-series)
Taking the simple average as the averag-
ing method, sets the averaging times per
measurement interval 4.
Yes
No
424 (01A8)
AVG move interval set
(3000-series)
Taking the average move as the averag-
ing method, sets the measurement inter-
val number.
Yes
No
425 (01A9)
AVG move (H) times set
(3000-series)
Taking the average move and high-speed
data output as the averaging method,
sets the averaging times per measure-
ment interval 4.
Yes
No
426 (01AA)
AVG move (L) times set
(3000-series)
Taking the average move and low-speed
data output as the averaging method,
sets the averaging times per measure-
ment interval 4.
Yes
No
427 (01AB)
Automatic detection set
(3000-series)
Sets work automatic detection function.
Yes
No
428 (01AC)
Automatic detection release
(3000-series)
Releases the settings of work automatic
detection function.
No
No
429 (01AD)
Automatic detection list request
(3000-series)
Requests the settings of work automatic
detection function.
No
Yes
430 (01AE)
3Z4L initialize (3000-series)
Clears the 3Z4L, sets the mm unit, sets
the memory switches, does not pro-
cesses statistics, and clears all statistic
memory in sequence.
Yes
No
431 (01AF)
Measurement condition set
(4000-series)
Sets measurement conditions.
Yes
No
432 (01B0)
Measurement condition release
(4000-series)
Releases measurement conditions that
have been set.
Yes
No
433 (01B1)
Measurement condition list
request (4000-series)
Requests the measurement conditions
that have been set and other settings.
No
Yes
434 (01B2)
Single run measurement start
(4000-series)
When the sample measurement condi-
tion is from 1 to 999, performs a single
run measurement and requests the mea-
surement results.
No
Yes
435 (01B3)
Deflection measurement start
(4000-series)
Starts a deflection measurement.
No
No
436 (01B4)
Continuous measurement start
(scan) (4000-series)
Starts a continuous measurement. The
scan notification method is used for
receive data.
No
Yes
437 (01B5)
Continuous measurement start
(interrupt (*2)) (4000-series)
Starts a continuous measurement. The
interrupt notification method is used for
receive data.
No
Yes
438 (01B6)
Measurement termination
(4000-series)
Terminates continuous measurement.
No
No (*1)
439 (01B7)
Data request (4000-series)
Requests measurement data in the idle
measurement status or the latch data
generated by the measurement com-
mand.
No
Yes
440 (01B8)
Forced positive zero
(4000-series)
Sets the forced zero direction to positive
(+).
No
No
441 (01B9)
Forced negative zero
(4000-series)
Sets the forced zero direction to negative
(–).
No
No
Sequence
No.
Communications sequence
name
Function
Ladder interface
Send word
allocation
Receive
word alloca-
tion
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...