A Standard System Protocol
R-114
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
This sequence clears the 3Z4L, sets the mm unit, and sets memory switches in sequence.
Send Data Word Allocation (3rd Operand of PMCR(260))
The send data word allocation is similar to that of sequence No. 401 (Memory Switch Set).
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
Memory switch settings will be ignored for this sequence for 5000-series and 6000-series Laser
Micrometers.
This general-purpose command is used to send data with a specified data length, and receive back
only OK. The terminator (CR) is automatically attached to the send data.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
3Z4L Initialize (4000-series) (Sequence No. 443 (Hex 01BB))
General-purpose Command 1 (4000-series) (Sequence No. 444 (Hex
01BC))
Offset
Contents (data format)
Data
+0
Number of send data words
(4 digits Hex)
0003 to 00FA (3 to 250 decimal)
+1
Send data byte length (4 digits Hex)
0001 to 01F0 (1 to 496 decimal)
The number of bytes of send data excluding the
terminator (CR)
+2 to
+249
Send data (ASCII)
Send data up to 496 bytes maximum
First word of
send data
Number of send data words
+0
+1
+2
+3
+248
+249
Send data
Send data byte length
Send data
Send data
•
•
Send data
CR
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...