A Standard System Protocol
R-66
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
V520 Connections
Shown below are the system settings of the V500-C11 and V520-R121 when this protocol is used.
Additional Information
The portions enclosed by boxes are used for this protocol.
V500-C11
• BCR Functions
• Host Interface
R-4-2
System Setting
Read trigger
Read control method
Prefix
Suffix
Bar code output
RS-232C port
Reader
Signal
Name
Signal
Name
Pin No.
Pin No.
V509-W011
Reader Cable
V520-R121
Serial Communications Unit/Board:
D-sub 9 pin female
V520-R121:
D-sub 9 pin female
FG
SD
RD
RTS
CTS
DSR
DTR
SG
SD
RD
RTS
CTS
DTR
SG
Serial Communications Board
(CS Series only)
Serial Communications Unit
(CS/CJ Series)
1
2
3
4
5
7
8
9
1
2
3
4
6
7
PLC PS
"READ SIGNAL INPUT", "ONLINE READ COMMAND"
"SINGLE READ", "CONTINUOUS READ"
NONE, "STX"
"ETX" , "CR "
"OUTPUT" , "NO OUTPUT"