A Standard System Protocol
R-14
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
605 (025D)
General-purpose broad-
cast with no conversion
and no response
A broadcast version of sequence No. 604.
No responses are received.
Yes
No
606 (025E)
Send/receive with ASCII
conversion and with
response
Send: Leftmost to right-
most word order
Receive: Leftmost to
rightmost word order
Converts specified data beginning with the
command code (MRC, SRC) into ASCII
and sends it to the specified Unit. The
response is converted into hexadecimal
and stored starting at the specified word.
Yes
Yes
607 (025F)
Send/receive with ASCII
conversion and with
response
Send: Rightmost to left-
most word order
Receive: Rightmost to
leftmost word order
Converts specified data beginning with the
command code (MRC, SRC) into ASCII
and sends it to the specified Unit. The
response is converted into hexadecimal
and stored starting at the specified word.
Yes
Yes
610 (0262)
Variable area read
Reads the contents of the specified number
of elements from the address of the speci-
fied variable type from the specified node
number and stores the data starting at the
specified word.
Yes
Yes
611 (0263)
Variable area write
Writes the contents of the specified number
of elements from the address of the speci-
fied variable type to the specified node
number.
Yes
Yes
612 (0264)
Variable area broadcast
send
Writes the specified number of elements
from the address of the specified variable
type using a broadcast.
Yes
No
613 (0265)
Variable area fill
Writes the same data from the address of
the specified variable type to the specified
node number.
Yes
Yes
614 (0266)
Variable area broadcast
send
Writes the same data from the address of
the specified variable type using a broad-
cast.
Yes
No
615 (0267)
Parameter area read
Reads the contents of the specified number
of elements from the address of the speci-
fied parameter area from the specified
node number and stores the data starting
at the specified word.
Yes
Yes
616 (0268)
Parameter area write
Writes the contents of the specified number
of elements from the address of the speci-
fied parameter area to the specified node
number.
Yes
Yes
617 (0269)
Parameter area broad-
cast write
Writes the specified number of elements
from the address of the specified parame-
ter area using a broadcast address.
Yes
No
618 (026A)
Unit properties read
Reads the Controller/component model
and communications buffer size from the
specified node and stores the data starting
at the specified word.
Yes
Yes
619 (026B)
Unit status read
Reads the Controller/component status
from the specified node and stores the data
starting at the specified word.
Yes
Yes
Sequence
No.
Communications
sequence name
Function
Ladder interface
Send word
allocation
Receive word
allocation
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...