R-53
A Standard System Protocol
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
R-3 Mitsubi
s
h
i Co
mputer
Link
Ma
ster
(A-c
o
m
pati
b
le
1C
Fra
m
e
, Model
1)
Re
f
R
-3-5
Str
ucture of
the Protocol
This sequence reads the bit (PV) data for the number of device points starting from the specified device
address for the specified device type (T, C) in the Mitsubishi Computer Link Module with the specified
station number (and the PLC number that follows), converts the data into hexadecimal, and stores it
starting from the specified word + 2 in the CS/CJ-series CPU Unit.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
Device Memory Batch Read as Bit Data (T/C Device Type)
(Sequence No. 807 (Hex 0327)) (Command Code: BR)
Offset
Contents (data format)
Data
+0
Number of send data words (4 digits hex)
Always 0005 hex (5 decimal)
+1
Station No.
(2 digits hex)
PLC No.
(2 digits hex)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
+2
Device type (4 digits hex)
Set the device type (2 characters) in ASCII.
+3
(Undefined) Device
No.
(3 digits hex)
Set the first read address of the device to read.
+4
(Undefined) Device
points
(2 digits hex)
Set the device points to read.
Offset
Contents (data format)
Data
+0
Number of receive data words
0003 to 00FA hex (3 to 250 decimal)
+1
Station No.
(2 digits hex)
PLC No.
(2 digits hex)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
+2
on
Read data (4 digits hex)
Stores the number read data converted into hexa-
decimal.
+0
+1
+2
+3
+4
(Undefined)
Number of send data words
PLC No.
Station No.
Device type
(Undefined)
Device No.
First word of
send data
Device points
Receive data
storage words
Number of receive data words
+0
+1
PLC No.
+2
on
Station No.
Read data
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...