A Standard System Protocol
R-92
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Additional Information
•
This sequence cannot be used to set the error lower limit (EL), error upper limit (EH), error
exclusion counter (CNT) of the error data exclusion function (centerless grinder function).
•
The following settings must be made together with this sequence; they cannot be set sepa-
rately.
Lower limit, upper limit
Multistep selection limit
Reference value, analog output scale number
Data output conditions, scheduled print timer
•
The limit value, reference value, and offset value can be set to 3 digits for the integer portion
and to 4 digits for the decimal portion.
This sequence releases the measurement conditions that have been set.
Send Data Word Allocation (3rd Operand of PMCR(260))
Send data word allocation is similar to that of sequence No. 407 (Measurement Condition Set).
However, only the setting Yes/No flags at +46 to +53 from the send data leading word can be used.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
•
The following conditions are used when the measurement conditions are released: Segment
becomes 1, measurement interval becomes 1, the number of sample measurement pulses
becomes 1.
•
The following conditions cannot be released with this sequence: error lower limit (EL), error
upper limit (EH), error exclusion counter (CNT) of the error data exclusion function (centerless
grinder function).
•
The following settings cannot be released separately using this sequence.
Lower limit, Upper limit
Multistep selection limit
Reference value, analog output scale number
Data output conditions, scheduled print timer
This sequence requests the measurement condition settings that have been set and other settings.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Measurement Condition Release (3000-series) (Sequence No. 408
(Hex 0198))
Measurement Condition List Request (3000-series)
(Sequence No. 409 (Hex 0199))
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...