- 68 -
UPS Management
Syntax
[RW_UPS_SECTION]
CFG_USE_UPS_MNG = <TRUE | FALSE>
CFG_NUM_OF_UPSES = <Number of UPSs>
CFG_NUM_OF_POWERSUPPLIES = <Number of PSUs>
CFG_MIN_NUM_OF_UPSES = <Minimum number of UPSs>
CFG_UPS_INPUT_LOST_DELAY = <Input Lost Delay>
CFG_UPS_COMMUNICATION_LOST_DELAY = <Communication Lost Delay>
CFG_UPS_ONLINE_DELAY = <Online Delay>
CFG_UPS_TIMED_SLEEP_PERIOD = <Sleep period>
CFG_UPS_GET_COMMUNITY_NAME = "<Get-request Community Name>"
CFG_UPS_SET_COMMUNITY_NAME = "<Set-request Community Name>"
CFG_UPS1_SERIAL_NUMBER = <UPS1 Serial number>
CFG_UPS1_CAPACITY = <UPS1 Capacity>
CFG_UPS2_SERIAL_NUMBER = <UPS2 Serial number>
CFG_UPS2_CAPACITY = <UPS2 Capacity>
CFG_UPS3_SERIAL_NUMBER = <UPS3 Serial number>
CFG_UPS3_CAPACITY = <UPS3 Capacity>
CFG_UPS4_SERIAL_NUMBER = <UPS4 Serial number>
CFG_UPS4_CAPACITY = <UPS4 Capacity>
CFG_UPS_USE_STATIC_IP = <TRUE | FALSE>
CFG_UPS_STATIC_IP1 = <UPS1 IP Address>
CFG_UPS_STATIC_IP2 = <UPS2 IP Address>
CFG_UPS_STATIC_IP3 = <UPS3 IP Address>
CFG_UPS_STATIC_IP4 = <UPS4 IP Address>
CFG_UPS_SVB_BOOT = <TRUE | FALSE>
CFG_UPS_SHUTOFF_DELAY = <Shutoff Delay>
CFG_AUTO_DETECT = <TRUE | FALSE>
Description
CFG_USE_UPS_MNG
Specify whether the UPS management by the EM card is enabled or not.
1: TRUE (enable)
0: FALSE (disable)
The default setting is "0" (disable).
CFG_NUM_OF_UPSES
Specify the number of UPSs managed by the EM card. The default setting is "0."
CFG_NUM_OF_POWERSUPPLIES
Specify the number of power supply units (PSUs) installed in the Blade Enclosure.
The default setting is "1."
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...