- 176 -
Boot Configuration
You can select either of EM or BIOS SETUP menu to configure boot device. Selecting
[Enable] allows you to specify the target boot device in [PXE Boot] or [iSCSI/FC/HDD
Boot] as shown below. If you want to specify the target boot device from BIOS SETUP
menu, select [Disable] for [Boot Configuration].
–
PXE boot
Select whether to specify PXE as the boot device.
–
iSCSI/FC/HDD Boot
Select whether to specify iSCSI/FC/HDD as the boot device. Select either one from
pull-down menu.
NOTES:
When [Boot Configuration] is set to "Enable", [PXE boot] must be
"Enable", or [iSCSI/FC/HDD Boot] must be other than "None".
B120a, B120b:
If [Boot Configuration] is set to "Disable" and [vIO Control] is set
to "Enable", the PXE boot is enabled on onboard LAN port 1.
B120d-h, B120d, B110d, B120e, B120e-h, B120f, B120f-h,
B120g-h:
Option Rom Scan is enabled on onboard LAN ports 1 and 2.
If any of the following device is installed, Option Rom Scan is also
enabled.
– [N8403-049(F)] 10GBASE Adapter (4ch)
– [N8403-051(F)] 10GBASE Adapter (4ch) (iSCSI-compliant)
– [N8403-061(F)] 1GBASE Riser Card (2ch)
– [N8403-062(F)] 10GBASE Riser Card (2ch)
– [N8403-064(F)] 10GBASE Riser Card (2ch) (iSCSI-compliant)
– [N8403-065(F)] 10GBASE Adapter (2ch)
– [N8403-067(F)] 10GBASE Adapter (2ch) (iSCSI-compliant)
– [N8403-081(F)] 1GbE (2ch) Riser Card
– [N8403-082(F)] 10GbE (2ch) Riser Card
– [N8403-083(F)] 10GbE (2ch) Riser Card (iSCSI-compliant)
– [N8403-084(F)] 10GBASE Adapter (2ch)
– [N8403-085(F)] 10GBASE Adapter (2ch) (iSCSI-compliant)
– [N8403-094(F)] 1GbE (2ch) Riser Card
– [N8403-095(F)] 10GbE (2ch) Riser Card
– [N8403-096(F)] 10GbE (2ch) Riser Card (iSCSI-compliant)
– [N8403-097(F)] 10GbE (2ch) Adapter
– [N8403-098(F)] 10GbE (2ch) Adapter (iSCSI-compliant)
– [N8403-099(F)] 10GbE (4ch) Adapter
– [N8403-100(F)] 10GbE (4ch) Adapter (iSCSI-compliant)
If you have already changed the parameter on BIOS SETUP menu
or Option ROM, set the [Boot Configuration] to "Enable", and
specify the priority appropriately.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...