- 38 -
Destination IP Address
Up to three destinations can be specified for sending SNMP trap. The destination is specified with
IP address.
The default value is "0.0.0.0" for three destinations.
Write the configuration file in the format as shown below.
-----------------------------------------------------------------
[RW_SNMP_SECTION]
CFG_IPADRESS01 = <IP Address 1>
CFG_IPADRESS02 = <IP Address 2>
CFG_IPADRESS03 = <IP Address 3>
-----------------------------------------------------------------
<IP Address 1>: IP address of destination 1
<IP Address 2>: IP address of destination 2
<IP Address 3>: IP address of destination 3
Above three IP addresses must be specified with decimal numbers and period such as
XXX.XXX.XXX.XXX (XXX: between 0 and 255).
<Example>
-----------------------------------------------------------------
[RW_SNMP_SECTION]
CFG_IPADRESS01 = 192.168.100.200
CFG_IPADRESS02 = 192.168.100.210
CFG_IPADRESS03 = 192.168.100.220
-----------------------------------------------------------------
NOTE:
The trap message will be sent to all the destinations specified.
Acknowledge Waiting Time and Retry Count of SNMP Trap
If the NEC ESMPRO Manager receives SNMP trap message, an acknowledge message is issued
from NEC ESMPRO Manager. If an acknowledge message is not received within the specified time,
the same trap is retransmitted. Specify the time to wait acknowledge message in unit of seconds and
the number of retries.
Write the configuration file in the format as shown below.
-----------------------------------------------------------------
[RW_SNMP_SECTION]
CFG_ACK_WAIT_TIME = <Ack Waiting Time>
CFG_MAX_RETRY = <Max Retry-Number>
-----------------------------------------------------------------
<Ack Waiting Time>: Acknowledge waiting time of SNMP trap (unit: second)
<Max Retry-Number>: Maximum retry number of SNMP trap
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...