- 58 -
CFG_DHCP_BASE_IP
DHCP server in EM card distributes IP addresses to management I/F of CPU blades and
switch modules. CFG_DHCP_BASE_IP specifies the base IP address. Then addresses are
assigned as shown below.
–
CPU blade installed in slot #1: Base a0
–
CPU blade installed in slot #2: Base a1
–
CPU blade installed in slot #3: Base a2
:
–
CPU blade installed in slot #8: Base a7
–
Switch module installed in slot #1: Base a8
–
Switch module installed in slot #2: Base a9
:
–
Switch module installed in slot #6: Base a13
CFG_DHCP_GATEWAY
DHCP server in EM card distributes default gateway to management I/F of CPU blades
and switch modules. CFG_DHCP_GATEWAY specifies the IP address of the default
gateway. Specify "0.0.0.0" when not using gateway. If distributing IP address to UPS
through DHCP server of EM card, do not specify "0.0.0.0" because the UPS must have the
default gateway address.
CFG_DHCP_NTPSRV
DHCP server in EM card can distribute external NTP server to management I/F of CPU
blades and switch modules. CFG_DHCP_NTPSRV Specifies the IP address of external
NTP server.
CFG_PSU_MODE
Specify the power redundancy mode that the EM card uses.
<PSU mode>: power redundancy mode
(2: N+1 redundant mode, 3: N+N redundant mode)
The default setting is "3" (N+N redundant mode).
CFG_POWSAVE_MODE
Specify the power control policy in the power management provided by the EM card.
<Powersave mode>: power control policy
(2: CPU performance mode, 3: maintain redundancy mode, 4: recover redundancy mode)
The default setting is "2" (CPU performance mode).
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...