- 304 -
The confirmation message is displayed.
EXEC Update OK?
Y/N
Press [
] or [
] button to move cursor horizontally to switch selection between "Y" and "N".
To cancel update, put the cursor on "N" and press the [Enter] button. The screen goes back to [EM
Firmware Sub] menu without changing the setting.
To execute update, put the cursor on "Y" and press the [Enter] button.
The following screen appears when the update process normally starts.
Update Started
Press any button to go back to [EM Firmware Sub] menu.
If you select [2: EXEC Update] on [EM Firmware Sub] menu while update is being executed, the
following screen appears.
In Update
Press any button to go back to [EM Firmware Sub] menu.
IMPORTANT:
Updating by this feature is performed to an active EM.
After updating, the EM is rebooted automatically.
If two EM cards are installed, the active EM is switched to another EM
card by switchover feature.
If only one EM card is installed, a bridge feature and SNMP feature are
stopped while rebooting. Accordingly, the connection via management
LAN of CPU blades and switch module is temporarily disconnected.
In addition, system monitoring by NEC ESMPRO Manager is
temporarily disabled. If a timeout error occurs, connect them again after
the EM has rebooted.
When you select "USB" on Select Media menu but the USB memory is not installed, the following
message is displayed.
Install the USB memory in the USB port of the Blade Enclosure.
USB Memory
Not installed
The following message is displayed when the USB memory is installed but not connected with the
EM card.
Media
Not installed
Select "E" in [DVD] field on KVM/DVD Select menu.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...