11
-
vIO Control
MAC Addresses and WWN (World Wide Name)s of I/O ports and serial number and UUID of CPU
blade can be virtualized by using vIO Control. This is a part of Boot Control feature. Using this,
there is no need to reconfigure the settings of the network or storage devices after replacing blades
or I/O cards.
NOTES:
The vIO Control is not available on 120Bb-6, 120Bb-m6, 120Bb-d6,
140Ba-10, and B140a-T.
The option cards (I/O cards) available for the vIO Control are as
listed below:
– [N8403-018] Fibre Channel Controller (2ch)
– [N8403-021] 1000BASE-T (2ch) Adapter (iSCSI-compliant)
– [N8403-022] 1000BASE-T (4ch) Adapter (iSCSI-compliant)
– [N8403-034(F)] 8G Fibre Channel Controller
– [N8403-035] 10GBASE-KR Adapter (2ch)
– [N8403-049(F)] 10GBASE Adapter (4ch)
– [N8403-051(F)] 10GBASE Adapter (4ch) (iSCSI-compliant)
– [N8403-065(F)] 10GBASE Adapter (2ch)
– [N8403-067(F)] 10GBASE Adapter (2ch) (iSCSI-compliant)
– [N8403-072(F)] 10G Converged Network Adapter (2ch)
– [N8403-076(F)] Dual Port 1GBASE Adapter
– [N8403-077(F)] Quad Port 1GBASE Adapter
– [N8403-084(F)] 10GBASE Adapter (2ch)
– [N8403-085(F)] 10GBASE Adapter (2ch) (iSCSI-compliant)
– [N8403-097(F)] 10GbE (2ch) Adapter
– [N8403-098(F)] 10GbE (2ch) Adapter (iSCSI-compliant)
– [N8403-099(F)] 10GbE (4ch) Adapter
– [N8403-100(F)] 10GbE (4ch) Adapter (iSCSI-compliant)
You may need to update the CPU blade BIOS or the IO card
firmware to use the vIO Control. Refer to the NEC corporate site for
detailed information.
(page 206).
vIO Control in the NEC SigmaSystemCenter managing system
Using vIO Control in the system managed by NEC SigmaSystemCenter makes it possible to
reducing downtime and management cost by automizing N+1 failover, applying, releasing or
changing boot configurations appropriately depending on the work load of each blade in the system.
For detailed information, please contact your service representative.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...