- 310 -
If you select "2" on Select revision menu, the following menu appears.
EM1 to R0600
OK?
Y/N
Press [
] or [
] button to move cursor horizontally to switch selection between "Y" and "N".
To cancel copying, put the cursor on "N" and press the [Enter] button. The screen goes back to [EM
Firmware Sub] menu without changing the setting.
To execute copying, put the cursor on "Y" and press the [Enter] button.
The following screen appears when the copy process normally starts.
Preparing
EMFW Sync
The following screen appears when writing the firmware starts.
EMFW Sync
Started
IMPORTANT:
After updating, the target EM card is rebooted
automatically. If the updating is executed on the active EM card, the
active EM card is switched to another EM card by switchover feature.
NOTES:
The combination of firmware revision available for synchronization
is as follows:
EM card that performs synchronization: Rev 06.00 or later
Another EM card: Rev 02.00 or later
To use this feature, you must be able to connect with both of Web
consoles of Active EM card and Standby EM card.
If the Active EM card is earlier than Rev. 10.08 and the Standby EM
card is Rev. 11.xx or later, the EM cards are not synchronized to
Rev 11.xx or later. In this case, perform EM switchover to switch
between the Active EM and the Standby EM, then perform
synchronization.
You cannot undo this operation, therefore, take extreme care to
execute it.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...