31
-
Basic Setup in Configuration File
This section describes the basic setup in configuration file.
Overview
Various settings for EM card are saved in a dedicated configuration file (in text format).
File name: /var/nvdata/rw_poem.conf
To edit the configuration file, use Edit Configuration menu in Web console. (See Chapter 4, "Using
Web Console Feature" for details.) Or, you may use "vi" command.
NOTE:
A file that is created or edited on the other computer can be
transferred via ftp. In this case, use a character code "EUC", and line
feed code "LF" in the file.
The following format is commonly used in configuration file.
-----------------------------------------------------------------
[<section-name>]
<item-name> = <set-value>
-----------------------------------------------------------------
When a character string is used for <set-value>, the character string must be enclosed with double
quotation marks.
NOTE:
A line containing space characters only is ignored.
IP Address of EM Card
The two EM cards installed in Blade Enclosure use the four IP addresses in total. These addresses
are classified into two types; "Static IP" is determined by the slot to install the EM card, and
"Floating IP" is used by the active EM card regardless of the installation slot.
The last bit of "Static IP" corresponds to the installation slot.
The last bit of "Floating IP" is defined as "0" for active EM card and "1" for standby EM card.
Содержание N8405-019
Страница 4: ... ii ...
Страница 6: ... iv ...
Страница 8: ... vi ...
Страница 10: ... viii ...
Страница 12: ... x ...
Страница 19: ... xvii Collection using Command Line Console 352 Collection using NEC ESMPRO Manager 352 Others 353 ...
Страница 20: ......
Страница 231: ... 211 N8403 099 F N8403 100 F ...
Страница 233: ... 213 Figure 1 Example of conflict of vIO information occurred when backing up and restoring the configuration ...
Страница 235: ... 215 Figure 2 Example of conflict of vIO information occurred when restoring the configuration to other Blade Enclosure ...
Страница 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...
Страница 253: ... 233 NEC SigmaSystemCenter Enable or disable access from NEC SigmaSystemCenter The default is Disable ...
Страница 266: ... 246 Login to the web console of the UPS The default username and password is Username apc Password apc ...
Страница 267: ... 247 After login click Outlet Groups in the Configuration Click on the Oulet Group to be configured ...